Compact Data Logger: Monitoring Temperature, RH and Dew Point

Modelo: HD208



Compact data logger: monitoring temperature, relative humidity (RH) and dew point temperature. MKT – Mean Kinetic Temperature calculation. Optional with software according to FDA 21 CFR part 11.

The data loggers of the series HD208 are compact instruments for monitoring temperature, relative humidity (RH) and dew point temperature.

Usable in a wide spectrum of applications, are available in various models: with 1 channel for temperature only (depending on the model, the sensor can be internal, external fixed or external with cable); with 1 channel for temperature and relative humidity (combined probe fixed with cable); with 2 channels for temperature only (one external sensor with cable and internal sensor); with 2 channels: one for temperature and relative humidity (combined probe cable) and one for temperature only (internal sensor. All models can be supplied with or without LCD display. The logging function is extremely versatile; logging can be started and stopped manually, by means of the front buttons, or the start and stop date and time of acquisition can be programmed.

The delayed start capability allows starting the logging with a configurable delay time after pressing the button for the manual start. For each quantity detected, two configurable alarm thresholds can alert the user if the measure exceeds the configured parameters. The instrument automatically generates, after logging, a PDF report with charts of the variables collected and a CSV file with all measurements logged. The PDF and CSV files can then be copied to the PC via the USB port, without any dedicated software: the instrument is recognized as a USB flash drive. The basic application software HD35AP-S supplied with the instrument allows the configuration of the instrument, the real-time monitor of the measurements and the transfer of the acquired data into a database.

The connection to the PC does not require any installation of USB drivers, thereby ensuring compatibility with all versions of the Windows operating system. The HD35AP-CFR21 application software option allows the use of security features of the recorded data and configuration of the instrument in response to FDA 21 CFR part 11 recommendations.